Siemon adds baffle cabinet options for side-vented data center equipment

Nov. 15, 2013
Siemon has announced its new SidePOD and Baffle platform designed to support side-to-side ventilated active equipment and end of row (EoR) configurations in data center applications.

Network infrastructure specialist Siemon has announced its new SidePOD and Baffle platform designed to support side-to-side ventilated active equipment and end of row (EoR) configurations in data center applications.

An optional add-on to Siemon’s 48-inch deep VersaPOD (VP2) cabinets, the SidePOD creates the necessary clearance for proper airflow and cooling when using side-to-side ventilated switches such as Cisco Nexus 7018 Series Switches. The optional baffles can be mounted within the SidePOD to route cold air to the input side of the switch and route exhaust into the hot aisle. The SidePOD is also an ideal solution for expanding EoR (End of Row) configurations to increase capacity, asserts the company.

When added to EoR cabinets, the SidePOD enables use of full size Zero-U panels which provides up to 12U of vertical patching and/or high-capacity vertical cable management to optimize EoR functionality. The SidePOD is compatible with the VP2 side panels, so the EoR cabinet side panels can readily be transitioned to the SidePOD when added.

Siemon’s SidePOD door features a lockable latch that can be easily opened or closed with a single finger and multiple cable access opening in the lid that accept optional brush guards to provide overhead cable access to the Zero-U space. The unique angled design of the baffles allows them to be nested in the Zero-U space between VP2 cabinets to support both side intake and venting between adjacent cabinets.

Related story: 11 Steps to Holistic Data Center Design

Unlike most baffle solutions, Siemon notes that its modular baffle solution allows six of the eight available Zero-U spaces (75%) to be used concurrently for patching or cable management with the baffles installed. The reversible baffles can be installed in either orientation for proper airflow from cold to hot aisles. Siemon’s new SidePOD and Baffle solution has been fully validated via Computational Fluid Dynamics (CFD) modeling for proven performance under maximum operating conditions.

“In today’s data centers, we are seeing an increase of large side-vented chassis switches that are often deployed in end of row configurations,” says Dave Valentukonis, cabling support systems manager at Siemon. “While these switches provide more room and accessibility for cable management at the front and rear of the equipment, it is critical to maintain proper airflow. Siemon’s new SidePOD and Baffle solution are ideal for supporting these switch environments while still providing the cable management and patching benefits of VersaPOD’s Zero-U space.”

For more information on Siemon’s SidePOD and Baffle, visit: http://www.siemon.com/sidepod

Sponsored Recommendations

400G in the Data Center

Aug. 3, 2022
WHATS NEXT FOR THE DATA CENTER: 400G and Beyond

Power up your system integration with Pulse Power - the game-changing power delivery system

May 10, 2023
Pulse Power is a novel power delivery system that allows System Integrators to safely provide significant power, over long distances, to remote equipment. It is a Class 4 power...

The Agile and Efficient Digital Building

May 9, 2023
This ebook explores how intelligent building solutions can help businesses improve network infrastructure management and optimize data center operations in enterprise buildings...

Revolutionize Your Network with Propel Fiber Modules

Oct. 24, 2023
Propel Fiber Modules are your gateway to the future of connectivity.