Emerson enhances Liebert CRAC unit with chilled water-based system - Cabling Installation & Maintenance

Emerson enhances Liebert CRAC unit with chilled water-based system


Feb 1, 2009

Emerson Network Power's (www.liebert.com) Liebert CW is a chilled water-based computer room air conditioning unit (CRAC) designed to offer improved energy savings within large data centers. The Liebert CW is a precision cooling system available in upflow and downflow configurations, and in cooling capacities up to 181 kW.

The system, which uses existing building chilled water supply as the cooling source, offers precision cooling and humidity control matched to the needs of data center equipment. Larger downflow models are available with optional energy-efficient EC plug fans, which the company says can achieve the highest level of energy efficiency. Both upflow and downflow models in all capacities are available with optional variable speed drive fans to improve energy efficiency over standard fan operation.


The Liebert CW system uses existing building chilled water supply as the cooling source to provide precision cooling and humidity control matched to the needs of data center equipment.
Click here to enlarge image

A recent Emerson Network Power analysis of data center energy usage found that cooling systems comprised of cooling and air movement equipment can account for approximately 38% of energy consumption. Independent tests of the energy efficiency of different types of fan systems found that in raised-floor data centers, where the EC can be used to its best advantage, the plug fan offers the lowest annual operating cost.

Liebert CW also features a proprietary iCOM control system that enables multiple units to communicate and operate as one system, providing control of temperature and humidity across a room while optimizing the efficiency of the entire cooling system.

Ron Spangler, senior product manager, Liebert Precision Cooling/Emerson Network Power, comments, “Our performance test results showed that the EC plug fan saves 30% more energy compared to a centrifugal fan at full speed. When the iCOM controls lowered the fan speed by only 20%, EC plug fans provide 65% energy savings in large data centers with chilled water cooling systems.”

In large data centers with chilled water systems, an integrated approach to dissipating high heat can be applied by combining the room-level cooling offered by the Liebert CW and the targeted cooling provided by the Liebert XD heat density cooling solution. The CW provides base-level cooling and humidification while the heat generated by high-density, rack-mounted electronic equipment is removed at its source by the XD.

With the Liebert CW, which is based on the design of the Liebert Deluxe System/3 Chilled Water system, customers may also purchase remote monitoring service for critical support equipment. Remote monitoring enables Emerson Network Power's Liebert Services business to monitor systems, predict and troubleshoot potential issues, and diagnose and respond to problems. ?M.V.


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide