Finding the culprit in Category 5 links gone bad - Cabling Installation & Maintenance

Finding the culprit in Category 5 links gone bad


Oct 1, 1995

Sue (M.E.) Lemay, RCDD, Hubbell Premise Wiring Inc.

Problem

You have cabled and tested your entire horizontal cabling system to Category 5 basic link-performance parameters, from patch panel to wall jack, before starting up the system. But, once the system goes live, you have workstations that are unable to communicate properly with the network.

This is a cabling nightmare that can happen to the best of installers, and the cause of the problem is sometimes difficult to detect. Because modular patch cords that connect equipment to the network are omitted from basic-link testing, they are most likely the source of the problem.

Solution

You will need to determine if the modular cords are causing performance degradation. If so, replace them with cords whose performance has been verified either by the manufacturer or by use in an active system.

Procedure

This procedure assumes that the overall channel link consists of a wall jack, 90 meters or less of horizontal cable, a patch panel and 10 meters or less of modular patch cords.

1) Disconnect the horizontal cabling from the station equipment and the system equipment, leaving the patch cords plugged into the wall outlet and the patch panel.

2) Retest the near-end crosstalk performance of your cabling from both the workstation and the patch panel ends. If excessive near-end crosstalk is present, remove the cord on that end and test again, using the cord supplied with the test unit. If the tester records a pass for near-end crosstalk, replace the test cord with a known good cord and test again to verify.

3) If excessive near-end crosstalk is present when using the cords supplied with the test unit, you may have a more serious problem, such as electromagnetic interference. You should check for possible trouble sources that may have been introduced after the initial link testing.

4) The suspect modular cords can often be detected using a link-performance tester or through visual inspection:

--Verify that the cords were built using the correct pairing/pinning.

--Check that the cable has been assembled using Category 5 cable.

--Look for "skiving" that occurs when the plug is not positioned properly in the tool when crimping. Skiving occurs when the crimp tool scrapes a sliver of plastic from the side of pins 1 or 8, or both, which can prevent proper contact when the connector is plugged into a jack. [For more information, see "Locating bad crimps," July 1995, page 43. Ed.]

Although these visual inspections may help locate a problem, modular patch cords designed to operate in a Category 5 system require special assembly and testing techniques that must be followed to ensure correct performance. For these reasons, it is recommended that you use cords that have been factory-assembled and -tested.

Sue (M.E.) Lemay is technical services engineer at Hubbell Premise Wiring Inc., in Stonington, CT.

Click here to enlarge image

Patch cords wired to T568A are interchangeable with those wired to T568B. For the latter, white/green, green/white appear on pins 3 and 6 and white/orange, orange/white appear on pins 1 and 2, respectively. For cords assembled using solid conductor cable, different solid colors apply.


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide