Testing copper cable for noise - Cabling Installation & Maintenance

Testing copper cable for noise


Nov 1, 1995

Frank J. Derfler, Jr. and Les Freed

Problem

The copper cable link was tested and certified upon installation, but now that construction is completed and the building is occupied, the data-processing equipment connected to the cable consistently has problems. Retesting the link indicates that the problem is not with the cable or connectors: The problem may be that electrical noise is present in the link.

Solution

Measuring electrical noise on a copper cable is a straightforward procedure, but identifying its origin can be frustrating. Many potential noise sources exist in business environments and some or all of them may operate intermittently.

Procedure

1) Disconnect the cable from the data-processing equipment and connect the cable to a cable tester.

2) Take a noise reading. The lower the reading, the less the electrical noise. (The standard unit for noise measurement is millivolts calculated by the root-mean-square method.)

3) If a significant noise level is measured, determine its frequency range, because signals from common electrical sources often occupy specific frequency bands.

4) Using blueprints or other documents, trace the route of the cable run. Walk the route and look for noise sources in the indicated frequency range.

5) Systematically disconnect potential noise sources, retesting the cable after each shutdown. Keep in mind that turning off a device may not deactivate it. Check for built-in batteries or power supplies.

6) If the noise problem is intermittent, it may not always show up on the cable tester. In this case, it may be necessary to attach an impulse noise recorder to the cable.

7) Once the noise source is located, it may be necessary to reroute the cable away from it. If it is impossible to avoid electric motors, elevators, fluorescent lights or whatever is causing the problem, consider pulling shielded twisted-pair cable to replace the installed link.

Click here to enlarge image

Frank J. Derfler, Jr. is senior networking editor at PC Magazine. Les Freed is author of the Crosstalk communications program. This tip is adapted from their book, Get a Grip on Network Cabling.


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide