Otdr and index-matching gel help determine fibers throughput - Cabling Installation & Maintenance

Otdr and index-matching gel help determine fibers throughput


Aug 1, 1997

Wayne Gipson,

Gipson Fiber Optic Services Inc.

Problem

After fiber-optic cable is routed into a building and terminated, the other end then awaits connection at a future, and probably critical, time. In the meantime, how do you ensure that there is adequate throughput in the cable without time-consuming end-to-end testing with a power meter and light source? If these instruments are to be used for testing, then at least temporary attachment of connectors to the unterminated end of the cable is needed, which may take considerable time. Also, a visible-light-laser test unit may not be available, and its output is often difficult to see, particularly in a well-lit environment, or when singlemode fiber, with its small core size, is being deployed.

Solution

You can use an optical time-domain reflectometer (otdr) and index-matching gel to determine if there is throughput in the cable. This procedure provides a quick check that the cable has not been damaged during installation. Its rough results also afford a level of comfort to the installer or customer when the fiber is scheduled to be spliced or terminated at a later time.

Procedure

1) At the unfinished end of the cable, strip off the sheath and buffer tubing to expose a couple of feet of bare fiber.

2) Use scissors to cut about an inch off the end of the fiber. This will give the fiber end a rough cleave that will enhance the end-spike reflection on the otdr trace.

3) Turn on the otdr and set it for "real time"--in other words, set it so it is continually gathering data, so you will see changes in the measurements as they occur.

4) Attach the otdr to the fiber to be tested.

5) While one technician is watching the otdr screen, another at the fiber end dips the fiber into index-matching gel. The end spike on the otdr trace will change or disappear when the fiber is immersed in the gel, the otdr indicating that the optical fiber has a clear transmission path to its end.

6) Repeat for each fiber in the cable.

Click here to enlarge image

Dipping the unterminated end of a fiber into index-matching gel can help to roughly determine its throughput.

Click here to enlarge image

An otdr trace before the fiber is immersed in index-matching gel (a) shows a clear end-spike. When the end of the fiber is immersed in index-matching gel (b), the spike disappears, indicating a clear transmission path through the fiber.

Wayne Gipson is co-owner of Gipson Fiber Optic Services Inc. (Wichita, KS).


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide