Pros and con of fiber-to-the-desk - Cabling Installation & Maintenance

Pros and con of fiber-to-the-desk


Sep 1, 1997

4-pair vs. 25-pair cabling

Q: I attended the "Do we need zone cabling?" panel discussion at the bicsi conference in June. I left with the message that individual 4-pair drops were a better design choice than a 25-pair Category 5 cable. Comments?

Ross Bedbrook, RCDD

Bell Canada

Moose Creek, ON, Canada

A: Ah, yes, as moderator of that session, I remember it well. Brian Moffitt of Lucent Technologies presented a slide depicting a "600-Pair Consolidation Point," which George Weller of Steelcase later described as a "King Kong" consolidation point. amp`s Ken Hall concluded that "bicsi should drive zone cabling practices to ensure [that they are] designed and installed properly." Terry Cobb of Datacom Technologies explained that in a 4-pair cable, near-end crosstalk is measured from pair to pair, but in a 25-pair cable, near-end crosstalk is measured using a power-sum technique. Bob Jensen of dbi then reminded the group that there are no 25-pair connectors recognized in the tia/eia-568a standard; no field-test instruments available to test power-sum near-end crosstalk on 25 pair-cable; and no cabling install-ation requirements provided on how to break out the 25-pair into 4-pair bundles while minimizing crosstalk.

As for me, I am sticking to my closing statement at the session: "It sounds as if we still have some work to do on this one."

Donna Ballast is a communications analyst at the University of Texas

at Austin and a bicsi registered communications distribution designer (rcdd). Questions can be sent to her at Cabling Installation & Maintenance or at PO Drawer 7580, University of Texas, Austin, TX 78713; tel: (512) 471-0112, fax: (512) 471-8883, e-mail: ballast@utexas.edu.


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide