Zero-halogen cables


Oct 1, 1997

Q: I am trying to ascertain whether polyvinyl chloride (pvc) or other halogen-containing insulation is in any real danger of getting superseded in the foreseeable future by non-halogen types in the United States for wire and cable insulation applications. Any comments on this?

Prof. Edward D. Weil

Polytechnic University

Brooklyn, NY

A: Tests comparing pvc and zero-halogen conductors indicate that zero-halogen-insulated conductors have a delayed ignition, emit less dense smoke and less total smoke, are six times less corrosive than pvc conductors, are three times less toxic than pvc conductors, and have significantly lower carbon monoxide emission levels. However, without a regulatory mandate, I do not personally see low-smoke/zero-halogen cables gaining a foothold in the telecommunications-cable market in the United States. Why? Increased cost to the end-user.

I recently spoke with several manufacturers of telecommunications cable regarding what percentage of their total production and domestic sales were zero-halogen. Less than 1% was the answer I received.

Halogens

Halogens found in insulating materials include chlorine, bromine, and fluorine. The most common halogenated insulating material is polyvinyl chloride (pvc). Plasticized pvc compounds have been used for decades for insulation and jackets for building cables.

While halogens improve certain properties?flame, chemical and oil resistance?they also have some negative effects. During combustion of halogenated insulating materials, the gases produced react with moisture to form halogen acids. These acids?for example, hydrogen chloride and hydrogen bromide?create corrosion, smoke obscuration, and toxicity.

Donna Ballast is a communications analyst at the University of Texas

at Austin and a bicsi registered communications distribution designer (rcdd). Questions can be sent to her at Cabling Installation & Maintenance or at PO Drawer 7580, University of Texas, Austin, TX 78713; tel: (512) 471-0112, fax: (512) 471-8883, e-mail: ballast@utexas.edu.


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide