Combating electromagnetic interference - Cabling Installation & Maintenance

Combating electromagnetic interference


Nov 1, 1997

Q: We have a number of new communications (voice and data) cable installations and are constantly addressing problems with electricians installing cable and electrical devices adjacent to communications cable runs, causing electromagnetic interference (emi). I am in search of an industry-standard specification stating distances from cable to emi-causing devices. The electrician`s bible, the National Electrical Code (nec), only mentions a 2-inch clearance between power and communications cables. Because of this, electricians do not share my concern.

One example of the problems caused is found in a new-building installation using ladder trays for communications cable. Electricians have wired fluorescent lamps through the trays and mounted them immediately below. Please let me know of any publications that can help.

Dennis Leclerc

State of New Hampshire

Administration Services Bureau

Concord, NH

A: It doesn`t matter who was there first. When the channel fails due to emi, the irate user never calls the electrician. While it is unlikely that a bad ballast (no pun intended) would endanger the life of a network user, it could certainly wreak havoc on network connections.

The nec is a safety code and not a telecommunications cabling performance specification. The ansi/tia/eia-568a commercial building wiring standard of the Telecommunications Industry Association (Arlington, VA) is the most widely accepted performance specification in North America: It refers us to ansi/eia/ tia-569, the pathways and spaces standard, for pathway information.

You may be surprised to learn that the requirements in tia-569`s Table 10.4-1 will be missing in the newly published ansi/tia/eia-569a version of the document. Gone also is the interference ceiling of no more than 3.0 volt/meter throughout the usable bandwidth of the telecommunications cabling.

Your best bet on this one is not a code or an industry standard but a methods manual. The Telecommunications Distribution Methods Manual (1996 Edition) of bicsi (Tampa, FL), in Chapter 4--"Horizontal Cabling Systems," has a section on "Avoiding Electromagnetic Interference." To avoid emi, all pathways should provide clearances of at least

- 1.2 meters (4 feet) from motors or transformers,

- 0.3 meter (1 foot) from conduit and cables used for electrical-power distribution,

- 12 centimeters (5 inches) from fluorescent lighting.

Pathways should cross perpendicular to fluorescent lighting and electrical-power cables or conduits.

Avoiding potential sources of emi must remain a primary consideration for telecommunications design professionals. I suggest specifying the separation requirements between telecommunications pathways/cabling and sources of emi in the contract documents of your next project. And not by reference--spell it out in the contract.


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide