Update on plenum-rated ground wire - Cabling Installation & Maintenance

Update on plenum-rated ground wire


Aug 1, 1999

Ansi/tia/eia-607, the Commercial Building Grounding and Bonding Requirements for Telecommunications standard, was published in August 1994. Section 5.3.4 regarding bonding and sizing the telecommunications bonding busbar (TBB) states: "A TBB shall be an insulated copper conductor"...and the quest began. In my very first "Ask Donna" column (see January 1994, page 45), I was asked where to find a plenum-rated ground wire. There wasn`t any then, and there isn`t any now. But in the most recent committee draft, TR-41.7.2 has agreed to remove the word "insulated," hence allowing the designer to choose.

Another issue that has plagued our industry--sizing the TBB--is also being discussed within TR-41.7.2. Currently, tia/eia-607 requires the minimum TBB conductor size to be a No. 6 AWG with consideration given to a conductor as large as a No. 3/0 AWG; The IEEE Std. 241-1990 Grey Book requires a minimum of 2 MCM (thousand circular mils)/linear foot of run; The IEEE Std. 142-1991 Green Book gives an example of a 500-MCM copper conductor for the building; and The ABC of the Telephone provides the table on the right. It is a safe bet that there will be a conductor-diameter-to-length-of-run ratio provided in tia/eia-607a.

Also on the topic of tia/eia-607 revisions, BICSI will be submitting suggested configurations for the telecommunications main grounding busbar and TGB (telecommunications grounding busbar) developed by a BICSI Standards Committee Task Force. If adopted, this part of the revision would allow manufacturers to stock ground bars rather than make them to order, reducing the procurement delays that we are currently experiencing.

Click here to enlarge image

Donna Ballast is a communications analyst at the University of Texas at Austin and a bicsi registered communications distribution designer (rcdd). Questions can be sent to her at Cabling Installation & Maintenance or at PO Drawer 7580, the University of Texas, Austin, TX 78713; tel: (512) 471-0112, fax: (512) 471-8883, e-mail: ballast@utexas.edu.


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide