TIA-942-A takes another step closer to completion


Mar 9, 2011

During a meeting held on February 10, the TIA TR-42.1 Commercial Building Telecommunications Cabling Subcommittee took another step closer to finalizing TIA-942-A, the revision of the TIA's data center cabling standard. Jonathan Jew, who is president of J&M Consultants and is taking a lead role in the TR-42.1 group that is revising the standard, offered some particulars about the standard's progress as well as how it will differ from the original TIA-942.

During the February meeting, the final committee ballot reached resolution, which means the specifications now move on to what is known as an industry ballot. From there it goes through a default ballot befor finally being published. Based on the timeframes in which balloting takes place, Jew said, "I expect we should be able to get to a default ballot within a year and publish sometime in 2012." The TIA TR-42 Committee meets three times per year, and some subcommittees also hold interim meetings to advance standards under development.

Jew authored an article that was published in the May 2010 issue of Cabling Installation & Maintenance magazine, providing an update on the progress of TIA-942-A at that time. Most of the changes he mentioned in that article have been incorporated into the standard's current draft. Following is a list of the major changes in the current draft of TIA-942-A.

  • TIA-942-A is harmonized with the TIA-568-C standard series including the topology, terms and environmental classifications described in 568-C.0, as well as component specifications in TIA-568-C.2 and C.3.
  • The addenda, TIA-942-1 and TIA-942-2, have been incorporated into 942-A; those two addenda will be superseded by TIA-942-A.
  • Grounding and bonding content from TIA-942 has been removed and incorporated into TIA-607-B.
  • Administration content has been removed and incorporated into the proposed TIA-606-B.
  • Most content regarding cabinets/racks and power/telecommunications separation has been removed and incorporated into the proposed TIA-569-C.
  • Outside-plant pathways content has been removed and incorporated into TIA-758-B.
  • The 100-meter length limitation for optical-fiber horizontal cabling has been removed. Horizontal cabling distances for optical fiber are based on individual application requirements.
  • Category 3 and Category 5e are no longer recognized for horizontal cabling. The draft recognizes Category 6 and Category 6A balanced twisted-pair cable types for horizontal cabling. Both types of cabling are still permitted for backbone cabling.
  • The recognized multimode optical fiber cable for horizontal and backbone cabling has been changed to OM3 and OM4 850-nm laser-optimized 50/125-micron multimode fiber cable. OM1 and OM2 are no longer recognized in TIA-942-A.
  • The recognized optical-fiber connectors are LC for one or two fibers and MPO for more than two fibers.
  • The intermediate distribution area (IDA) has been added to the data center topology.
  • An allowance for midspan powering equipment in the zone distribution area (ZDA) has been removed.
  • A section on energy efficiency has been added.
  • The terms "equipment outlet" (EO) and "external network interface" (ENI) from the ISO/IEC 24764 standard have been added.

A section of the TIA's home page lists "Hot Standards." The TIA-942 and TIA-568-C standards regularly occupy the top spots in the short list of such standards. Before very much longer, TIA-942-A may be atop the TIA's list of most-purchased specifications.


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide