Fiber assemblies pass encircled-flux testing - Cabling Installation & Maintenance

Fiber assemblies pass encircled-flux testing


Apr 25, 2011

Siemon recently announced that a number of its fiber-optic assembly products have passed performance testing, conducted by an independent testing laboratory, in accordance with the encircled-flux launch conditions recently adopted by the TIA.

TIA-526-14-B Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant was "back-adopted" from part of an International Electrotechnical Commission (IEC) standard. That specification is titled IEC 61280-4-1 edition 2, Fibre-Optic Communications Subsystems Test Procedure Part 4-1: Installed Cable Plant - Multimode Attenuation Measurement. The IEC spec is where encircled flux was initially defined and referenced for multimode fiber testing.

Siemon explained that its MTP-based OM3 and OM4 plug-and-play assemblies passed the standards' insertion-loss and endface-geometry requirements with margins up to 60 percent. The tests were conducted by Expeior Laboratories. The testing was performed across several channel configurations, Siemon says, including MTP-to-MTP cable assemblies in OM4 and OM3 fiber grades, MTP-to-LC plug-and-play modules, MTP-to-LC fiber jumpers; LC fiber jumpers and MTO-to-MTP adapter plates.

Charlie Maynard, Siemon's fiber-optic product manager, said the high performance margins achieved - up to 60 percent - are important in high-bandwidth, multi-fiber array systems. "Contamination introduced int eh field as well as testing inconsistencies due to varied test equipment and reference-cord quality can make it difficult to ensure that the consistent performance levels of factory-terminated fiber assemblies are maintained when installed in the field."

Related story: TIA adopts encircled flux in new fiber-test standard


We Recommend

Skeletons in the telecom closet: The 10 scariest things I've seen this year

The 11 biggest cabling stories of 2011

Free app calculates loss budget

Reference poster dissects 802.11n

Fiber installation courses available online

Counterfeit cable exposed

Making the switch from 62.5- to 50-micron fiber

Telecom grounding and bonding standard published by NECA and BICSI

Free poster highlights 10 fiber-safety rules


Most Popular Articles
Top Blog Posts

TIA sets objectives for 40G over twisted pair

Cancer patients miss surgery due to cable theft

Cable tech finds 500-pound bear in customer’s basement

Nearly-electrocuted copper-cable thief speaks remorsefully

House explosions, captured on video, blamed on cable theft

Modified U.S. Army drone spies on WiFi users

Turn a wiring cabinet into a liquor cabinet


Receive Free E-mail Newsletters from Cabling Installation & Maintenance

Want to hear about more articles like this one? Sign up for our free email newsletters.



Email:

First Name:

Last Name:

Promo Code (optional):

Country:

Available Newsletters:
Cabling News

Data Centers Report

Contractor Report

 


Cabling Installation & Maintenance Topic and Resource Categories:

Data CentersCabling Standards
Network CableConnectivity Technologies
Network ProtocolsIP Convergence
WirelessDesign, Installation & Testing
Current IssueArchives
Cabling BlogBuyer's Guide