Hewlett-Packard offers 3-phase PDU with power monitoring

March 19, 2009--Hewlett-Packard's 14.4kVA Monitored PDU connects to a 50-amp (40-amp usable), 3-phase circuit using a Hubbell CS8365C connector. This power distribution unit has a single input and twelve C19 outputs for connecting to a variety of devices, such as servers, storage, networking, and other infrastructure equipment.

March 19, 2009--Hewlett-Packard's 14.4kVA Monitored PDU
connects to a 50-amp (40-amp usable), 3-phase circuit using a
Hubbell CS8365C connector. This power distribution unit has a single input and twelve C19 outputs for connecting to a variety of devices, such as servers,
storage, networking, and other infrastructure equipment. The PDU takes
3-phase input power and delivers single-phase power to equipment.

The unit lets administrators and facility personnel monitor current
draw directly at the rack and at the PDU. A local power display lets users set up and configure the PDU, and monitor the PDU power for RMS current, status, and overload conditions. HP says AC power can be evenly distributed across the three phases of AC power to maximize efficiency, minimize infrastructure costs, and reduce the chance of overloading a branch circuit breaker.

The PDU chassis includes two serial ports--one for local set-up and
configuration and one for attachment of the optional remote management
module. The local user interface consists of a basic control panel that
includes a two-digit 7-segment display, a recessed reset button, a
scroll/invert button and six segment-dedicated LEDs. An optional PDU
Management Module provides remote monitoring capabilities; it can be
configured to send e-mail alerts and alert traps to SNMP management
programs to monitor up to two PDUs through the network connector or
serial connector located on the front of the management module.

Sold through authorized dealers, the HP Power Distribution Unit with
Power Monitoring is available now with a U.S. Internet price of $1,499.
The optional PDU Management Module has a U.S. Internet price of $199.

On the Web: www.hp.com/go/infrastructure

Sign up for our eNewsletters
Get the latest news and updates
Little Beaver Inc.
A hydraulic earth drill with a high-torque anchor handle and utility anchor adapter can significantly improve safety for anchor installation.
Enabling a one-person install, the earth drill has several advantages over manually setting drive rods or using anchor crankers.
Creative Composites Group
These Tower Tech XR cooling towers use evaporative cooling to remove heat generated within the data center by IT equipment. Composite cooling towers are more compact and significantly lighter than metal towers. They arrive at a data center site pre-built.
Data center designers shouldn’t sleep on the benefits of fiberglass construction materials.