Siemon offers 48-port Z-Max Cat 6A patch panel

Oct. 15, 2009
The 48-port 1U patch panels meet or exceed all 10GBASE-T and category 6A/class EA performance requirements, including those for alien crosstalk.

October 15, 2009 -- Siemon has introduced a 48-port, 1U version of its Z-Max 6A modular patch panel. Available in both category 6A/class EA shielded and unshielded options, the Category 6A modular panels are designed to combine robust 10Gb/s performance with ultra-high density patching. This provides users additional flexibility to deploy high-performance, category 6A/class EA cabling infrastructures within strict space limitations, while saving valuable rack and cabinet space in the data center or telecommunications room, maintains the company.

The Z-Max 6A panel outlet is central to the patch panel’s performance in high-density applications. The outlets feature exclusive diagonally-oriented insulation displacement connector (IDC) contact technology that maximizes distance between contacts within side-stacked outlets compared with traditional rectangular contact layouts. Maximizing pair-to-pair separation between adjacent outlets enhances noise resistance in both the shielded and unshielded systems and minimizes alien crosstalk even in the most dense category 6A/class EA patching environments.

The patch panels also feature the company’s modular Quick-Snap panel design, which allows panel outlets to be quickly snapped into place or removed to speed initial deployment and subsequent moves, adds and changes. Designed specifically for the Z-Max panels, the Cat 6A panel outlets utilize the same best-in-class termination process as Z-Max hybrid outlets. Using the spatent-pending Z-Tool, both shielded and unshielded panel outlets can be terminated in as little as 60 seconds from start to finish, including cable preparation, and can then be easily snapped into the panel.

The Z-Max 6A panels’ Quick Snap design also makes them suitable for use with Siemon’s Z-Max 6A pre-terminated trunking cable assemblies. Equipped with Z-Max 6A panel outlets, Siemon trunks are configured specifically to the customer need, allowing permanent links in high density environments like data centers to be quickly deployed to minimize installation time. This exact-fit approach, combined with the Quick Snap panel design, significantly reduces installation time - up to 75% compared to individually field-terminated channels, maintains the company. By consolidating multiple cabling channels, Siemon trunks also improve cable management and pathway space utilization in raised floor or overhead cable tray as well as facilitating efficient moves, adds and changes.

The durable panels are constructed of lightweight, high strength steel with industrial black finish, scratch/fade resistant port marking and user-friendly integrated cable management. Port identification is enhanced through the panel’s high visibility magnifying labeling system.

The Z-Max 6A shielded panels also feature Siemon’s integrated Quick Ground technology, which automatically grounds the shielded modules to the panel upon insertion, eliminating additional outlet grounding steps. Both Z-Max 6A shielded and unshielded panels are available as complete kits including patch panel, panel outlets, and all necessary accessories. Empty panels are also available for use with Z-Max pre-terminated trunking cable assemblies.

Siemon’s Z-MAX 6A line includes complete end-to-end category 6A/class EA systems in both shielded and unshielded configurations. The full Z-MAX 6A channel consists of Z-MAX 6A outlets Siemon category 6A cable and Z-MAX 6A patch panels, as well as Smart-Plug-equipped Z-MAX 6A patch cords, which feature a design integrating a precisely tuned printed circuit board (PCB) into every plug for enhanced signal and unparalleled end-to-end system performance.

On the Web:
www.siemon.com

Sponsored Recommendations

Power up your system integration with Pulse Power - the game-changing power delivery system

May 10, 2023
Pulse Power is a novel power delivery system that allows System Integrators to safely provide significant power, over long distances, to remote equipment. It is a Class 4 power...

Network Monitoring- Why Tap Modules?

May 1, 2023
EDGE™ and EDGE8® tap modules enable passive optical tapping of the network while reducing downtime and link loss and increasing rack space utilization and density. Unlike other...

The Agile and Efficient Digital Building

May 9, 2023
This ebook explores how intelligent building solutions can help businesses improve network infrastructure management and optimize data center operations in enterprise buildings...

400G in the Data Center

Aug. 3, 2022
WHATS NEXT FOR THE DATA CENTER: 400G and Beyond