Separating Category 8 fact from fiction

March 12, 2014
Analyst examining the structured cabling market compares talk versus reality when sizing Cat 8 up against other copper and fiber cabling.

Sarah McElroy (profile), a research analyst with IHS, recently published a document titled “Category 8: Unraveling Fact from Fiction.” With IHS’s permission, we are reproducing that document here ...

In the few months that I have been researching the network cabling market, I have heard a wide variety of perspectives and opinions about the pending introduction of the Category 8copper cable, which will support 40-Gbit/sec Ethernet. Never have I encountered a topic where I have heard such opposite viewpoints expressed. In the case of Cat 8, the “facts” I hear from one supplier have completely contradicted the “facts” I hear from another, especially when relating it to a comparable fiber offering. For this reason, I have set out to clear up some misperceptions associated with Cat 8 copper cable.

Cat 8 is even larger in diameter than Cat 6A: TRUE

While it is true that Cat 8 is slightly bigger than Cat 6A cables, the difference in size is far less than what is often claimed. A source close to the standards creation has stated that Cat 8 cables will only be a few hundredths of a millimeter larger in diameter. When looking at the two cables side-by-side, the naked eye would not recognize the difference in size.

Compared to fiber, however, there is certainly no contest with regard to size. Fiber-optic cables are often anywhere between one-fourth to one-half the size of a copper cable. One fiber is about the same size as a human hair, so these cables will inevitably be only a fraction of the size of copper cables, especially since they do not require shielding.

Size is a concern due to the limited space available in a patch panel or switch, especially as densities increase. For example, there are now 48-port patch panels, and with the current size of copper cables and connectors, there is barely room to fit all those cables. There is really no room for cable or connector size to expand if high densities are to be achieved. Airflow is also a concern because it becomes increasingly difficult to get adequate airflow to switches with higher densities of cords attached to them.

The increased weight of Cat 8 cable will cause problems for cable management and switches: FALSE

Cat 8 cable will indeed be slightly heavier than Cat 6A cable. However, a source involved with standards creation claims that the increased weight amounts only to a couple more pounds per reel of cable. This small amount of extra weight is not anticipated to cause problems for cable management or to create a dangerous amount of weight pulling on switches. Fiber-optic cable, by comparison, is much lighter than copper and, additionally, will never suffer from the added weight of shielded layers.

Cat 8 requires more power than fiber-optic cable to run at 40-Gbit/sec speeds: TRUE

It is true that copper-based systems require more power to run at high speeds than fiber-optic-based systems do. The power that will be required to run a 40GBase-T system can be depicted as a U-shaped graph, with power on the vertical axis and frequency on the horizontal axis. Thus, there is a certain range of ideal frequencies—at the bottom of the “U”—at which the power needed is lowest. While it is possible to optimize the power used by the Cat 8-supported 40GBase-T system, it will still always exceed that required by a fiber-based 40G system.

When thinking about power usage, heat becomes an additional consideration. Because copper-based systems require more power, they also generate more heat than fiber-based systems, and contribute to the need for increased data center cooling efforts.

Cat 8 cables will be standardized for a shorter length: TRUE

The Telecommunications Industry Association (TIA) did a survey that showed cable lengths of 50 meters or less will cover 90 percent of the cabling needs in a data center. However, to make absolutely sure that they did not run into the same problems that prolonged the application of Category 6A-supported 10GBase-T, the Institute of Electrical and Electronics Engineers (IEEE) decided that the standard for 40GBase-T be created for 30 meters. This may be completely adequate for some data centers; however, those needing cables longer than 30 meters will be limited by this length, and may find fiber-optic cabling to be the most viable option.

Cat 8 does not have as much longevity as fiber-optic cabling: TRUE AND FALSE

It is true that fiber-optic cabling lasts more than one cycle of install, and because of this, it usually lasts much longer than the typical copper installment. Therefore, when looking purely at the length of time a deployment will last, fiber usually wins. However, Cat 8 copper (along with all other category cables) provides another type of longevity in that it supports Base-T applications that autonegotiate. Therefore, it has the ability to endure a multistage deployment. Because of Base-T’s autonegotiation capabilities, customers are able to upgrade electronics gradually instead of installing an entire new deployment all at once in order to implement a 40-Gbit/sec system.

Copper is easier and better understood than fiber: HONESTLY, THIS IS SUBJECTIVE

People don’t like change, and that is just a fact. It is frequently claimed that copper is easier to install and all installers can do it. You do not need any extra training or certification to install or maintain a copper infrastructure. Proponents of Cat 8 will continue to cite this as a compelling reason to stick with a copper infrastructure to satisfy 40-Gbit/sec needs as opposed to switching to fiber optics. To be fair, there are many differences, and terminating fiber cables is definitely a bit trickier. However, fiber has been around long enough by this point that there are many skilled installers, the fiber isn’t as fragile as it used to be, and many of the concerns surrounding installation difficulties no longer apply.

While fiber continues to be more competitive, copper continues to strive to achieve the quality and speeds that fiber handily provides. Will contractors and customers stick with what they know, or try something new? We will have to wait and see. Hopefully we won’t have to wait too long. The TIA will likely have standards completed by the end of 2015, while the IEEE standards are predicted to be completely shortly after, perhaps by the beginning of 2016.

Sarah McElroy can be reached at [email protected] or 512-582-2039.

Sponsored Recommendations

Power up your system integration with Pulse Power - the game-changing power delivery system

May 10, 2023
Pulse Power is a novel power delivery system that allows System Integrators to safely provide significant power, over long distances, to remote equipment. It is a Class 4 power...

The Agile and Efficient Digital Building

May 9, 2023
This ebook explores how intelligent building solutions can help businesses improve network infrastructure management and optimize data center operations in enterprise buildings...

400G in the Data Center

Aug. 3, 2022
WHATS NEXT FOR THE DATA CENTER: 400G and Beyond

Network Monitoring- Why Tap Modules?

May 1, 2023
EDGE™ and EDGE8® tap modules enable passive optical tapping of the network while reducing downtime and link loss and increasing rack space utilization and density. Unlike other...