Datwyler improves fibers in single-mode cables

Datwyler upgrades its indoor, universal and outdoor cables.

Smaller bending radii, improved attenuation properties and higher transmission quality are the significant benefits passed on to Datwyler's customers, the company reckons, as it switches to two new single-mode fibers based on G.652.D (BLO) and ITU-T G.657.A2 fiber.

According to a press release, in the future, the company's fiber-optic (FO) indoor cables -- previously incorporating bend-optimized single-mode ITU-T G.657.A1 fiber -- will be supplied as standard by Datwyler with bend-optimized G.652.D bend-loss optimized (BLO) fiber, or optionally with bend-optimized ITU-T G.657.A2 fiber. The latter has been tried and tested in FTTx networks and data centers, notes Datwyler, with users benefitting from a low bending radius of 10 to 7.5 mm for added operational safety.

The company clarifies that its FO Universal and FO Outdoor series cables will now no longer be offered with ITU-T G.657.A1 fiber but, from now on, in addition to ITU-T G.652.D, will be available with G.652.D BLO fiber.

"The convincing argument for this new fiber is not only that it has improved attenuation properties, e.g. ≤0,21 dB/km @ 1550 nm (installed), but also that it incorporates the essential advantages of the 'old' fibers, namely the comparatively large-mode field diameter of G.652.D and the low bending losses of G.657.A1," commented a Datwyler representative.

The representative added that planners and network operators of LANs, data centers, FTTx and city networks "will gain from using the cables with the new G.652.D (BLO) fibers, in that they no longer have to allow for additional attenuation losses when connecting fibers of different mode field diameters. These fibers therefore give them and the companies installing them a greater safety buffer."

For more information, visit www.cabling.datwyler.com.

Sign up for our eNewsletters
Get the latest news and updates
Little Beaver Inc.
A hydraulic earth drill with a high-torque anchor handle and utility anchor adapter can significantly improve safety for anchor installation.
Enabling a one-person install, the earth drill has several advantages over manually setting drive rods or using anchor crankers.
Creative Composites Group
These Tower Tech XR cooling towers use evaporative cooling to remove heat generated within the data center by IT equipment. Composite cooling towers are more compact and significantly lighter than metal towers. They arrive at a data center site pre-built.
Data center designers shouldn’t sleep on the benefits of fiberglass construction materials.