Pros and con of fiber-to-the-desk

Q: I attended the "Do we need zone cabling?" panel discussion at the bicsi conference in June. I left with the message that individual 4-pair drops were a better design choice than a 25-pair Category 5 cable. Comments?

4-pair vs. 25-pair cabling

Q: I attended the "Do we need zone cabling?" panel discussion at the bicsi conference in June. I left with the message that individual 4-pair drops were a better design choice than a 25-pair Category 5 cable. Comments?

Ross Bedbrook, RCDD

Bell Canada

Moose Creek, ON, Canada

A: Ah, yes, as moderator of that session, I remember it well. Brian Moffitt of Lucent Technologies presented a slide depicting a "600-Pair Consolidation Point," which George Weller of Steelcase later described as a "King Kong" consolidation point. amp`s Ken Hall concluded that "bicsi should drive zone cabling practices to ensure [that they are] designed and installed properly." Terry Cobb of Datacom Technologies explained that in a 4-pair cable, near-end crosstalk is measured from pair to pair, but in a 25-pair cable, near-end crosstalk is measured using a power-sum technique. Bob Jensen of dbi then reminded the group that there are no 25-pair connectors recognized in the tia/eia-568a standard; no field-test instruments available to test power-sum near-end crosstalk on 25 pair-cable; and no cabling install-ation requirements provided on how to break out the 25-pair into 4-pair bundles while minimizing crosstalk.

As for me, I am sticking to my closing statement at the session: "It sounds as if we still have some work to do on this one."

Donna Ballast is a communications analyst at the University of Texas

at Austin and a bicsi registered communications distribution designer (rcdd). Questions can be sent to her at Cabling Installation & Maintenance or at PO Drawer 7580, University of Texas, Austin, TX 78713; tel: (512) 471-0112, fax: (512) 471-8883, e-mail: [email protected].

Sign up for our eNewsletters
Get the latest news and updates
Little Beaver Inc.
A hydraulic earth drill with a high-torque anchor handle and utility anchor adapter can significantly improve safety for anchor installation.
Enabling a one-person install, the earth drill has several advantages over manually setting drive rods or using anchor crankers.
Creative Composites Group
These Tower Tech XR cooling towers use evaporative cooling to remove heat generated within the data center by IT equipment. Composite cooling towers are more compact and significantly lighter than metal towers. They arrive at a data center site pre-built.
Data center designers shouldn’t sleep on the benefits of fiberglass construction materials.