CommScope demos technical feasibility of Category 8 copper cabling system

Feb. 14, 2013
The demonstration took place at the recent IEEE 802.3 NGBASE-T study group meeting in Phoenix, Arizona.

CommScope announced that it has successfully demonstrated the technical feasibility of Category 8 cabling for enterprise networks. The company calls the demonstration "a step along the path towards a viable 40GBase-T system for data center applications."

The demonstration took place at the recent IEEE 802.3 NGBASE-T study group meeting in Phoenix, Arizona. A technical contribution to the study group titled, “Category 8 Structured Cabling Channel Demonstration by CommScope,” described the feasibility of the concept.

Related: CommScope exec voices skepticism of 40GBase-T over Cat 7A

CommScope verified its proof-of-concept solution for a viable 40 Gigabit per second (Gbps) Ethernet channel by utilizing prototype Category 8 RJ-45 connectors and copper twisted pair cables. All components of the next generation data center infrastructure concept were designed by engineers in CommScope labs, according to a press release.

The company said the two aspects outlined by thie proof-of-concept demonstration include commonly used RJ-45 connectors and bandwidth capability of proposed Category 8 cabling. CommScope notes that today, 10GBase-T continues to gain broad acceptance in the server and access layers; the company anticipates that bandwidth growth will necessitate a 40GBase-T solution in the future.

“We believe this demonstrated solution shows the real market potential for customers to eventually take advantage of 40G transmission rates over copper twisted-pair based media with cable and connector types they are familiar with today,” commented Richard Mei, director of transmission solutions at CommScope.

CommScope supports BASE-T technology in conjunction with RJ-45 connectivity as a widely accepted and cost-effective networking option in both data center and commercial building environments. The company contends that its Category 8 proof-of-concept demonstrates that data center operators will be able to extend their preferred mean of communication technology for 40G.

“The Systimax brand is a recognized leader in next generation networking with a history of innovation,” added CommScope's Mei. “We will continue to work with customers to help deploy appropriate solutions for the continued emergence of 10GBase-T applications. When a 40G cabling solution does become market-ready and available, they will have the right infrastructure to provide a sensible migration path.”

Related: CommScope document questions suitability of Cat 7A cabling for 40GBase-T

Sponsored Recommendations

What you need to know about 6A cabling

Aug. 3, 2022
Did you know that Category 6A cable is the best choice for structured cabling?

Cat 6A Frequently Asked Questions

April 29, 2024
At CommScope we know about network change and the importance of getting it right. Conclusion Category 6A cabling and connectivity.

Cat 6A Hard Facts

Aug. 3, 2022
At CommScope we know about network change and the importance of getting it right. Conclusion Category 6A cabling and connectivity.

Why CommScope 6A?

Nov. 7, 2022
Inside buildings and across campuses, network demands and economics are changing. As applications like IoT, 10GBASE-T, multigigabit Wi-Fi 6/6E/7 and PoE++ become more common, ...