Electri-Flex Liquatite conduits now CSA certified 'Heavy-Duty'

Electri-Flex Liquatite conduit types LA, ZHLA, and CBLA are now CSA certified as “Heavy-Duty.”

Electri-Flex (Roselle, IL) announced that its Liquatite conduit product types LA, ZHLA, and CBLA now conform to C22.2 No. 56-17 Annex A “Heavy-Duty” for CSA certification.

The certification's “Heavy-Duty” annex requires liquidtight flexible metal conduit to pass additional tension, cold flexibility, connector compatibility, and crush tests.

The Heavy-Duty listing from CSA means that these conduit types passed vigorous testing, above and beyond standard CSA and UL 360 standards, across the following parameters, per the manufacturer:

  • Tension - Withstands greater tension force.
  • Tested to 500 lbs. which is a 66% greater force applied versus standard CSA and UL testing.
  • Cold Flexibility - Superior flexibility in cold temperatures.
  • Placed in a freezer for 4 hours, 300% longer cold exposure and then wrapped around a smaller mandrel with a 30-37% tighter bend radius.
  • Connector Compatibility - Stronger connector attachment.
  • Pulling force of 350 lbs., which is 133% greater force applied versus UL testing.
  • Crush - Excellent crush strength.
  • Meets the same tough standards as UL, 1,500 – 2,000 lbs. depending on conduit diameter.

Electri-Flex Liquatite products that meet CSA Annex A “Heavy-Duty” include Types LA, ZHLA, CBLA and CSA. Only conduit trade sizes ½” through 4” qualify for the (HD) “Heavy-Duty” designation.

Specifically, per the company:

  • Type LA is a UL Listed, CSA Certified, general purpose, flexible steel conduit that offers outstanding protection against wet and oily conditions. Working Temperatures: UL: -30°C to 80°C Dry / 60°C Wet / 70°C Oil and CSA: -30°C to 75°C Air /75°C Oil
  • Type ZHLA is a UL Listed, CSA Certified, low fire hazard solution conduit, offering halogen-free, low smoke, and low flame spread properties. Working Temperatures: UL: -40°C to 80°C Air / 60°C Wet / 70°C Oil and CSA: -40°C to 60°C Dry / 60°C Oil
  • Type CBLA is a UL Listed, CSA Certified, Computer Blue LA, ideally suited for computer rooms and data center installations. Working Temperatures: UL: -30°C to 80°C Dry / 60°C Wet / 70°C Oil and CSA: -30°C to 60°C Air / 60°C Oil

To learn more, download the Electri-Flex CSA Certified “Heavy-Duty” Conduits sales sheet at www.electriflex.com/resource-library/.

Sign up for our eNewsletters
Get the latest news and updates
Little Beaver Inc.
A hydraulic earth drill with a high-torque anchor handle and utility anchor adapter can significantly improve safety for anchor installation.
Enabling a one-person install, the earth drill has several advantages over manually setting drive rods or using anchor crankers.
Creative Composites Group
These Tower Tech XR cooling towers use evaporative cooling to remove heat generated within the data center by IT equipment. Composite cooling towers are more compact and significantly lighter than metal towers. They arrive at a data center site pre-built.
Data center designers shouldn’t sleep on the benefits of fiberglass construction materials.